MODELING NOTES FOR ASHRAE STANDARD 140 

A. SOFTWARE INFORMATION
1. SOFTWARE VENDOR: 
   REM/Rate LLC.

2. SOFTWARE NAME: 
   REM/Rate

3. SOFTWARE VERSION: 
   2025

4. OPERATING SYSTEM REQUIREMENTS:
   Windows 10
   Windows 11

5. APPROX HARD DISK SPACE REQUIRED FOR INSTALLATION:
   3GB

6. MINIMUM RAM REQUIRED FOR SOFTWARE OPERATION:
   8GB

7. MINIMUM DISPLAY MONITOR REQUIREMENTS:
   1024x768

8. OTHER HARDWARE OR SOFTWARE-RELATED REQUIREMENTS:
   REM/Rate serves as an input generation, data management, HPXML
   translation, and results reporting application. Energy simulation
   calculations for the ANSI/ASHRAE Standard 140 tests are performed 
   using OpenStudio-ERI, which utilizes OpenStudio-HPXML and EnergyPlus. 

   ANSI/ASHRAE Standard 140 test cases employed for RESNET software 
   accreditation consist of building fragments that do not represent 
   complete residential buildings and therefore do not satisfy the input 
   validation requirements normally enforced for production residential 
   energy ratings. 

   For execution of the ANSI/ASHRAE Standard 140 accreditation tests,
   REM/Rate provides a dedicated accreditation mode that: 

   - Reads the accreditation test-case building files directly from a 
     specified directory. 
   - Generates HPXML representations of the building files without 
     applying normal residential model validation checks. 
   - Invokes OpenStudio-ERI in ANSI/ASHRAE Standard 140 mode. 
   - Passes the required options to bypass standard residential input 
     validation and apply the assumptions prescribed for the ANSI/ASHRAE 
     Standard 140 test suite. 
   - Collects simulation results and exports them to a spreadsheet format 
     for comparison against ANSI/ASHRAE Standard 140 reference results. 

   The ANSI/ASHRAE Standard 140 test results submitted herein were 
   produced using the same automated accreditation workflow that is used
   by REM/Rate to maintain RESNET accreditation.

   The simulation calculations themselves are performed by 
   OpenStudio-ERI/OpenStudio-HPXML and EnergyPlus. REM/Rate does not 
   modify the underlying simulation algorithms, ANSI/ASHRAE Standard 140 
   test implementations, or EnergyPlus calculation engine for the purpose
   of ANSI/ASHRAE Standard 140 testing. 

   The ANSI/ASHRAE Standard 140 test results submitted by REM/Rate were 
   validated using the RESNET ANSI/ASHRAE Standard 140 accreditation 
   spreadsheet. All required test cases produced results within the 
   acceptance ranges specified by the accreditation procedure.

B. REPORT BLOCK FOR ALTERNATIVE MODELING METHODS
   NONE

C. REPORT BLOCK FOR EQUIVALENT MODELING METHODS
   NONE

D. REPORT BLOCK FOR USE OF NON-SPECIFIED INPUTS
   NONE

E. REPORT BLOCK FOR OMITTED TEST CASES AND RESULTS
   NONE

F. REPORT BLOCK FOR CHANGES TO SOURCE CODE FOR THE PURPOSE OF RUNNING THE 
   TESTS, WHERE SUCH CHANGES ARE NOT AVAILABLE IN PUBLICLY RELEASED VERSIONS OF 
   THE SOFTWARE
   REM/Rate includes an accreditation testing mode intended solely for
   execution of the ANSI/ASHRAE Standard 140 test suite used for RESNET
   software accreditation. This functionality is not exposed during normal
   residential energy rating operation. 

   This mode bypasses the normal residential building validation checks 
   performed by REM/Rate and allows generation of HPXML files 
   corresponding to ANSI/ASHRAE Standard 140 building fragments. It also 
   invokes OpenStudio-ERI using options that bypass standard input 
   validation and apply ANSI/ASHRAE Standard 140 assumptions. 
  
   These changes affect only the preparation and execution of test cases.
   No modifications were made to the underlying simulation algorithms, 
   ANSI/ASHRAE Standard 140 test implementations, or EnergyPlus 
   calculation engine used to generate the reported results.
   
   The ANSI/ASHRAE Standard 140 test cases required for RESNET
   accreditation contain assumptions that are not represented directly
   in the REM/Rate building file. Accordingly, limited modifications are 
   made to the generated HPXML prior to simulation to ensure that the 
   model presented to OpenStudio-ERI conforms to the requirements of the 
   ANSI/ASHRAE Standard 140 test procedures.
   
   These adjustments are consistent with the assumptions required by the
   RESNET ANSI/ASHRAE Standard 140 accreditation procedure and are applied
   solely for execution of the accreditation test suite.
   
   Specifically, the generated HPXML is adjusted as follows:
   - Add the ApplyASHRAE140Assumptions extension flag used by
     OpenStudio-ERI.
   - Add plug loads and associated schedules, as required.
   - Add miscellaneous loads and associated schedules, as required.
   - Set roof area explicitly rather than deriving roof area from
     roof pitch.
   - Remove CO2 index reporting inputs.
   - Add wood siding to above-grade walls as per the test requirements.
   - Set attic ventilation rate explicitly as per the test requirements.
   - Set building occupancy to zero as per the test requirements.
   - Remove residential appliance definitions not applicable to the
     ANSI/ASHRAE Standard 140 test case being executed.

G. REPORT BLOCK FOR ANOMALOUS RESULTS